Frequently asked questions - PNOZmulti configurable control systems
As simple as a PNOZ, as flexible as a controller
Below you will find answers to the following:
PNOZmulti - General
PNOZmulti - Software
PNOZmulti - Hardware
PNOZmulti - General
How fast is the PNOZmulti (reaction time)?
What fuse protection is required on the PNOZmulti?
On the PNOZmulti, what is meant by "coated version"?
What should be considered when connecting enable switches to PNOZmulti?
Die Fault LED´s der PNOZmulti Ausgangsmodule blitzen kurz auf. Im Fehlerstack ist aber kein Fehler dokumentiert.
PNOZmulti - Software
I have forgotten my PNOZmulti program password. What do I do now?
What does the 't' stand for on many of the switch types in the PNOZmulti Configurator?
Why can't I display the error stack on the PNOZmulti Configurator?
Can T0 to T3 be used for a different purpose?
On the PNOZmulti Configurator, why doesn't the help start automatically?
From Version 3 of the PNOZmulti Configurator there is an option to give an "activated" input a filter time.
What do the following mean: overall check sum, program check sum and data check sum, in reference to the CRC check sum?
Once the user program has been downloaded, for how long does it remain stored in the PNOZmulti base unit when operating voltage is not applied?
PNOZmulti - Hardware
How high is the current consumption of an input on the PNOZ m1p base unit?
Where is the 0 Volt terminal on the PNOZ mi1p?
Why do the LEDs at A1, A2, 24V, 0V, CI- and CO- not light?
Are the terminators and connectors in the PNOZmulti, PNOZpower and PNOZplus series compatible? Are the connectors available separately?
Are terminals A2 and 0V galvanically isolated?
Can pressure sensitive mats be used on the PNOZmulti/m1p base unit?
What distinguishes the signal outputs, on the PNOZ mc1p for example, from the safety outputs?
What is the function of the I/Os CI+, CI-, CO+, CO-?
Why does the FAULT LED light up red after the chip card is exchanged?
What's the purpose of the OA0 terminal?
With Cat. 4 is it permitted for two identical test pulses to be linked to adjacent inputs?
How high is the switching capability of the relay outputs on the PNOZmulti, PNOZ mo2p and PNOZ mo4p?