|
|
Latest information - The very latest from Pilz
|
| Latest information |
 |
Ostfildern, Nov 11, 2011
New generation of operator terminals PMI 509 and 515 with enhanced processors – Higher performance for diagnostics and visualisation
Higher performance and extended memory capacity thanks to enhanced 600 MHz RISC OMAP processors and high-contrast displays: These are the features of the new generation of Pilz operator terminals PMI (Pilz Machine Interface). The diagnostic units are now available in display sizes from 3.5" and with 5.7" screen diagonal. In conjunction with safe control technology from Pilz, they provide effective visualisation and troubleshooting support when production faults occur.
|
 |
Ostfildern, Sep 30, 2011
The all-in-one motion control solution from Pilz – PMCprimo Drive P control system: Compact and powerful
With the control system PMCprimo DriveP Pilz is expanding its portfolio in the motion control sector. The new control system is a combination of motion control card and servo amplifier. PMCprimo DriveP is designed for applications with several axes and high requirements in terms of performance and synchronised movements. The compact dimensions, a fast processor, digital inputs and outputs, a clear software tool and the expandability with the PMCprotego S safety card are features of the new control system.
|
 |
Ostfildern, May 18, 2011
Graphics Program Editor PASmulti, part of the automation system PSS 4000 - Program creation is simple, quick and intuitive
The automation system PSS 4000 from Pilz now includes the graphics Program Editor PASmulti. This can be used to create both standard and safety-related automation projects quickly and easily and to configure the control system PSSuniversal PLC.
A comprehensive library of safety-related and standard software blocks enables a high level of reusability.
|
 |
Ostfildern, Mar 23, 2011
Pilz at Interpack 2011 - Solutions for complete packaging plants
At this year's Interpack Pilz will be exhibiting complete solutions for primary, secondary and end packaging machines, both for new machines and retrofit.
In addition to solutions comprising safe sensor technology, safe control systems and diagnostic options, the company will also have information on its range of services - from the production of individual safety concepts through to CE certification.
|
 |
Ostfildern, Feb 28, 2011
New insulation monitor PMD s20 is simpler to operate - Easy-turn operation
PMD s20 has now been added to the portfolio of electronic monitoring relays in the PMDsigma series from Pilz. With it, it is simply turn and click to set all the values, which can then be stored on a chip card. This gives users the flexibility to transfer data for other devices.
PMD s20 monitors the electrical safety of insulated
supplies – for operating theatres, offshore installations or the electroplating industry for example – and prevents power failures due to short circuits.
|
 |
Ostfildern, Feb 22, 2011
Safe proximity switch PSENini from Pilz expands the sensor technology portfolio - Safe, non-contact monitoring
Pilz has now added the safe proximity switch PSENini to its safe sensor technology portfolio. PSENini detects the approach of metallic objects without using contacts. Safe detection is provided even on multiple position
applications - with long cams or rotational movements. The non-wearing technology is particularly suitable for high switching frequencies and guarantees high productivity and a long service life.
PSENini are available in an IP67 design and so are suitable for use under difficult industrial conditions such as heavy soiling, shock or vibration.
|
 |
Ostfildern, Nov 17, 2010
Line inspection device PLIDdys prevents unintended power-up in the event of an error - Safe power-up guaranteed
The Pilz range now includes a safe line inspection device: on single-channel two-wire connections, PLIDdys ensures safe power-up and maximum safety on long cable routes of up to three kilometres. With PLIDdys, unintended power-up or plant start-up can be excluded in the event of an error. This is particularly beneficial on interlinked plants or on plant sections distributed over a wide area, which may not always be clearly visible. The extremely compact design means that existing plants can easily be retrofitted.
|
 |
Ostfildern, Oct 12, 2010
New version of the protection and measuring system PSENvip with dynamic muting function - More productive presses
With the control systems from the automation system PSS 4000 and the new version of the camera-based protection and measuring system PSENvip, Pilz now offers a safety solution specifically for press brakes, which is of interest for new machines and retrofits alike. Operating speeds can be adjusted to optimum level, cycle counts are significantly higher and diagnostics are user-friendly, increasing the machines’ availability and cost-effectiveness.
|
 |
Ostfildern, Oct 12, 2010
Safe electronic rotary cam arrangement for greater flexibility - Electronics deal mechanics a knockout blow
As part of the automation system PSS 4000 Pilz now offers a safe electronic rotary cam arrangement for simple, flexible control of mechanical presses. The safe electronic rotary cam arrangement consists of the control system PSSuniversal PLC from the automation system PSS 4000 and press blocks, which have now been expanded to include the new cam controller block and a specific rotary encoder.
|
 |
Ostfildern, Oct 7, 2010
Wireless system InduraNET p now with IP67 wireless module - Efficient wireless communication in all circumstances
A remote IP67 module is now available for the wireless system InduraNET p (Industrial Radio Network) from Pilz. The remote module for the wireless system has been specially developed for use under difficult industrial conditions and can withstand water, dirt and heavy vibration. As a result, reliable wireless data transmission is now available on mobile plant and machine sections.
|
 |
Ostfildern, Oct 7, 2010
Safety relay PNOZmulti Mini now expandable - Connection guaranteed
Additional base units are now available for the configurable safety relays PNOZmulti Mini. These enable quick, easy connection of communication and safe link modules, as well as contact expansion modules. As a result, interlinked and decentralised plants can now also be monitored safety using PNOZmulti Mini.
|
 |
Ostfildern, Jul 29, 2010
Simplifying the calculations of safety functions - new version of the PAScal Safety Calculator enables libriaries to be imported in Sistema format
Not everyone's a mathematical genius. That's why, as far as possible, it's important to simplify the complex calculation of safety functions in accordance with EN ISO 13849-1 and EN/IEC 62061. So Pilz has once again enhanced its PAScal software tool, used to verify the functional safety of machinery. With improved libraries, which store the safety-related characteristic data for all Pilz products, the new version v1.5.0 is even more practice-oriented. It also allows you to import libraries from other manufacturers in Sistema format, the similar software assistant produced by the IFA (Institute for Occupational Safety and Health of the German Social Accident Insurance).
|
 |
Ostfildern, Apr 15, 2010
Safe, analogue and decentralised - Automation system PSS 4000 with safe processing of analogue values
The new automation system PSS 4000 now includes safe analogue input modules, which significantly extend the system’s application range. Modular, fine-granular hardware gives the automation system flexibility, enabling the design to be tailored exactly to the requirements of the plant or machine.
|
 |
Ostfildern, Apr 15, 2010
Compact modules for decentralised I/O system PSSuniversal - Economical solution
Compact modules are now available for the decentralised I/O system PSSuniversal.
Modules are available with 16 digital standard inputs and 16 digital standard outputs; there are also modules with digital inputs and outputs.
The three new compact modules are also compatible with the electronic and base modules in the system PSSuniversal.
|
 |
Ostfildern, Apr 15, 2010
Digital input modules for the control system PNOZmulti - Highest level of safety for up to 64 sensors
The IP67 digital, decentralised input module PDP67 F 8DI ION is now available, enabling a higher number of sensors to be connected safely, even outside the control cabinet. As a result, decentralised monitoring of all sensors in the field can be connected to the configurable control system PNOZmulti.
|
 |
Ostfildern, Mar 10, 2010
Manipulation impossible – Pilz makes safety gate monitoring safe
The non-contact safety gate systems PSENslock are a safe alternative to existing mechanical technology. With an electromagnetic holding force of up to 1000 N, PSENslock units prevent swing gates and sliding gates from being opened unintentionally. The actuator is manipulation-proof, providing added safety.
|
 |
Ostfildern, Mar 10, 2010
Switches for greater network efficiency - New components for the Ethernet infrastructure of PSS 4000
Pilz can now supply the new infrastructure components PSSnet S, for networking the new automation system PSS 4000 via the Ethernet system SafetyNET p. These Industrial Ethernet Switches enable the network topology to be adapted flexibly to the plant layout. Star, tree and ring topologies are available as architectures. As an extra benefit, both the availability and the expanse of the network can be increased.
|
 |
Ostfildern, Mar 10, 2010
PITmode switch from Pilz - Dual-function operating mode selector switch
Pilz has expanded its range of operator and visualisation systems with the operating mode selector switch PITmode. The PITmode provides two functions in one compact unit: selection of operating mode and authorisation control for machine access. The operating mode selector switch has been developed for use in plant and machinery with a range of control sequences and operating modes.
|
|
|

|